Model: HNAG1000
Detection: Nitric Oxide ($NO$)
Detection Principle: Electrochemical
Detection range: 0-1ppm (Atmospheric monitoring), 0-250ppm (1000ppm), 0-2000ppm, 0-2000ppm (5000ppm)
The HNAG1000 split-type nitric oxide gas detector is engineered for high-accuracy real-time monitoring of NO leaks and concentration levels in demanding industrial environments. By separating the meter host from the gas detection probe via a customizable connection line, this unit offers flexible installation options tailored to complex operational spaces.

Equipped with an imported electrochemical sensor and high-performance microcontroller, the detector ensures rapid response speeds, exceptional stability, and low zero drift. It effectively measures trace amounts in atmospheric monitoring as well as higher concentrations in heavy industrial emission applications.
Designed for seamless integration into industrial automation networks, the system includes dual simultaneous signal outputs and comprehensive safety certifications.
• Modular Plug-and-Play Probe: Allows individual component replacement without scrapping the entire unit, significantly reducing long-term maintenance costs.
• Explosion-Proof & Rugged Housing: Built with a die-cast aluminum enclosure providing IP66 protection against water splashes and rain, meeting Ex d IIC T6 explosion-proof standards.
• Multiple Output Options: Features standard 4-20mA current output, RS485 digital communication using the MODBUS RTU protocol, and relay switching outputs to directly link with ventilation fans or solenoid valves.

• High-Definition Color Display: A 2.5-inch TFT screen clearly presents real-time gas concentration, environmental temperature, and humidity.
• Infrared Remote Control: Enables parameter calibration and alarm adjustments without opening the housing cover in hazardous locations.
• Comprehensive Alarms: Supports on-site sound and light alarms alongside remote software monitoring capabilities.

To ensure optimal performance and rapid response times, follow these professional installation guidelines:
• Location: Install the detector within one meter of potential gas leakage points, positioned according to the specific gravity of the target gas.
• Orientation: Mount the probe facing downwards, keeping the sensor surface vertical to the ground. Ensure the installation height is greater than 30 cm from the ground to prevent water splashing.
• Wiring: Use a three-core shielded cable for 4-20mA connections or a four-core cable for RS485 communication, ensuring the shielding layer is properly grounded.

This reliable gas monitoring solution is widely deployed across various heavy industries and municipal facilities, including:
• Chemical plants and petrochemical refineries
• Thermal power plants and steel manufacturing
• Smelting plants and boiler rooms
• Environmental protection bureaus and atmospheric monitoring stations

The standard transmission distance for both 4-20mA current signals and RS485 digital communication reaches up to 1 kilometer using properly shielded cables.
Yes, the unit is fully compatible with various control alarms, PLCs, DCS systems, and DDC systems via its standard 4-20mA and RS485 MODBUS outputs.
Calibration can be easily executed safely using the standard infrared remote control, which allows operators to adjust settings without opening the explosion-proof enclosure cover.
Under normal operating conditions and regular maintenance, the electrochemical sensor typically lasts between 3 to 5 years.
Yes, the unit features an IP66 enclosure rating and supports external rain shields, making it fully weather-resistant for outdoor industrial applications.

The HNAG1000-PM is an industrial fixed dust detector featuring a high-precision laser scattering sensor. With IP66 protection, explosion-proof casing, and RS485/4-20mA outputs, it ensures real-time, accurate PM monitoring for harsh environments.

Engineered for hazardous industrial sites, the HNAG1000-PM-M provides continuous online particulate matter monitoring. With an IP66 rugged enclosure, ExdIICT6 certification, and seamless PLC integration via RS485/4-20mA, it guarantees absolute safety.

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

HNAG900-NH3 portable ammonia gas detector adopts imported Honeywell sensor with pump suction design. It supports multiple optional NH3 measuring ranges, equips flexible sampling probe, multi-mode data transmission including 4/5G, LoRa and Bluetooth, supports local data storage & USB export, ideal for industrial leak check, indoor air monitoring and on-site environmental testing.

This HNAG900 handheld H2S hydrogen sulfide gas detector adopts imported sensor, 0-10ppm measuring range, built-in vacuum suction pump. It supports real-time curve display, USB data export, optional 4/5G, LoRa and Bluetooth transmission, equipped with bendable sampling probe, long-life battery, widely used for industrial leak check, indoor air quality inspection and on-site environmental gas testing.

HNAG900 portable CO carbon monoxide gas detector supports multiple measurement ranges for atmospheric & industrial gas monitoring. Equipped with imported Honeywell sensor, built-in vacuum suction pump, 27cm bendable sampling probe. It supports USB data export, 4/5G, LoRa, Bluetooth transmission, with large data storage, audible alarm, stable performance for factory leak check, ambient air inspection and industrial safety detection.

This pump-type portable CH4 methane detector equips Honeywell high precision sensor, supports multiple measuring ranges for methane testing. It adopts color LCD curve display, supports 4/5G cloud upload, LoRa and Bluetooth transmission for remote viewing, onsite printing and USB data export. 5400mA large battery offers long runtime, optional high/normal temperature probes, ideal for industrial methane leak check, environmental testing and indoor gas monitoring.

The split-type hydrogen cyanide gas detector utilizes advanced electrochemical sensing technology tailored for industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type phosphine gas detector utilizes advanced electrochemical sensing technology tailored for industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type hydrogen gas detector utilizes advanced electrochemical and thermal conductivity sensing technology tailored for industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type ammonia gas detector utilizes advanced electrochemical and thermal conductivity sensing technology tailored for industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type nitric oxide gas detector utilizes advanced electrochemical sensing technology tailored for atmospheric and industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type nitrogen dioxide gas detector utilizes advanced electrochemical sensing technology tailored for flue gas and atmospheric monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

Ensure workplace safety with our split type sulfur dioxide gas detector. Featuring electrochemical/flue gas sensors, Exd IIC T6 explosion-proof design, and real-time display, it delivers precise 24/7 SO2 monitoring for harsh industrial environments.

Ensure industrial safety with our split type carbon monoxide gas detector. Featuring advanced electrochemical/NDIR sensors, Exd IIC T6 explosion-proof design, and real-time digital display, it provides precise 24/7 CO monitoring for harsh environments.

High-accuracy split-type H2S gas detector (0-20000ppm) with reliable electrochemical sensor. Features 4-20mA/RS485 outputs, Ex d IIC T6 explosion-proof design, and real-time monitoring for harsh industrial setups. Ensure safety and compliance.

High-accuracy split-type O2 gas detector for continuous industrial monitoring. Features a flexible remote probe, real-time alarms, and precise ranges (0-30%vol, 0-100%vol, 0-10000ppm). Built with explosion-proof housing for tough environments.

This HNAG920-NH3 handheld single ammonia gas detector provides 12 optional NH3 measuring ranges from 0-10ppm up to 0-100%Vol. It supports auto 180° screen rotation, 4G/WiFi/Bluetooth/LORA wireless transmission, Type-C rechargeable design, 4-side LED alarm lights, durable PC+TPU housing, and allows mobile data viewing & Bluetooth printing for chemical plants, livestock farms and refrigeration workshop hazardous gas monitoring.

Skyeaglee HANG-900-CH4-C portable methane gas detector with catalytic detection 0-100%LEL, IP65, Ex ib II CT4 Gb. Expandable to 6 gases, 5400mAh, USB data export. Professional methane gas monitor for oil, coal, petrochemical.

Explore the Portable pump - assisted diffusion - type hydrogen gas detector. This detector combines pump - assisted and diffusion - type features, offering high - precision hydrogen detection.

The HNAG1000-PM is an industrial fixed dust detector featuring a high-precision laser scattering sensor. With IP66 protection, explosion-proof casing, and RS485/4-20mA outputs, it ensures real-time, accurate PM monitoring for harsh environments.

Engineered for hazardous industrial sites, the HNAG1000-PM-M provides continuous online particulate matter monitoring. With an IP66 rugged enclosure, ExdIICT6 certification, and seamless PLC integration via RS485/4-20mA, it guarantees absolute safety.

Category: Products Flue gas pretreatment system Simple Pretreatment Online Monitoring System Key words: Products Model: SK/MIC-7500 Measurement object: CO2/Ex/CH4/CO/H2S/O2/N2/NH3/CL2/H2/He/Ar/CH2O/O3/NO/NO2/SO2/C2H4O/PH3/COCL2/HBR/HCL/HCN/CLO2/SIH4/...

HNAG900-NH3 portable ammonia gas detector adopts imported Honeywell sensor with pump suction design. It supports multiple optional NH3 measuring ranges, equips flexible sampling probe, multi-mode data transmission including 4/5G, LoRa and Bluetooth, supports local data storage & USB export, ideal for industrial leak check, indoor air monitoring and on-site environmental testing.

This HNAG900 handheld H2S hydrogen sulfide gas detector adopts imported sensor, 0-10ppm measuring range, built-in vacuum suction pump. It supports real-time curve display, USB data export, optional 4/5G, LoRa and Bluetooth transmission, equipped with bendable sampling probe, long-life battery, widely used for industrial leak check, indoor air quality inspection and on-site environmental gas testing.

HNAG900 portable CO carbon monoxide gas detector supports multiple measurement ranges for atmospheric & industrial gas monitoring. Equipped with imported Honeywell sensor, built-in vacuum suction pump, 27cm bendable sampling probe. It supports USB data export, 4/5G, LoRa, Bluetooth transmission, with large data storage, audible alarm, stable performance for factory leak check, ambient air inspection and industrial safety detection.

This pump-type portable CH4 methane detector equips Honeywell high precision sensor, supports multiple measuring ranges for methane testing. It adopts color LCD curve display, supports 4/5G cloud upload, LoRa and Bluetooth transmission for remote viewing, onsite printing and USB data export. 5400mA large battery offers long runtime, optional high/normal temperature probes, ideal for industrial methane leak check, environmental testing and indoor gas monitoring.

The split-type hydrogen cyanide gas detector utilizes advanced electrochemical sensing technology tailored for industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type phosphine gas detector utilizes advanced electrochemical sensing technology tailored for industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type hydrogen gas detector utilizes advanced electrochemical and thermal conductivity sensing technology tailored for industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type ammonia gas detector utilizes advanced electrochemical and thermal conductivity sensing technology tailored for industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type nitric oxide gas detector utilizes advanced electrochemical sensing technology tailored for atmospheric and industrial monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

The split-type nitrogen dioxide gas detector utilizes advanced electrochemical sensing technology tailored for flue gas and atmospheric monitoring. Featuring a modular design with high precision, it delivers reliable leakage detection, real-time concentration display, 4-20mA and RS485 outputs, and robust IP66 protection for harsh industrial environments.

Ensure workplace safety with our split type sulfur dioxide gas detector. Featuring electrochemical/flue gas sensors, Exd IIC T6 explosion-proof design, and real-time display, it delivers precise 24/7 SO2 monitoring for harsh industrial environments.